Electrical Strip Safety

By John Howell

There were several fires caused by plug strip on Cape Cod this year, two with fatal injuries.

A  power strip combines several sockets attached to the end of a flexible cable, allowing multiple devices to be plugged in. The biggest safety concern with power strips is their potential for fire if overloaded.

Precautions for fire prevention:

· Do not plug power strips into other power strips to make what is sometimes called a “piggy back” or “daisy chain.”

· Only use power strips that have a built-in surge protector (i.e., voltage regulator) and preferably also a built-in circuit breaker to prevent circuit overload.

· Do not use power strips for appliances with heating elements, such as electric space heaters or bench-top cooking appliances.

· Assure that all power strips meet recognized testing requirements. Although Underwriters Laboratories (UL) is the most recognizable label, there are many other testing laboratories that test and label electrical equipment.

· Do not plug power strips into extension cords; plug them directly into wall sockets. Extension cords are not to be used for permanent applications.

· A heavy reliance on power strips is an indication that you have too few outlets to address your needs. Have additional outlets professionally installed.

Determining power strip capacity:

Know the capacity of the circuit and the power requirements of all electrical items plugged into the power strip and other outlets on the circuit. In order to determine this:

· Determine the capacity of your power strip (in amps or watts).

· Determine the load (i.e. power requirements) of all the electrical items plugged into the power strip in amps or watts.

· Add up the power requirements. Assure that the total does not exceed 80% of the rated capacity of your power strip. Also, determine the same for the circuit serving the power strip to assure that it is not overloaded.

Example: A power strip is rated for 15 amps/120 V. (Note that watts = amps x volts.)

· 15 amps x 120 volts = 1800 watts.

· 1800 watts x 80% = 1440 watts that may be used.

Always unplug them when leaving your jobsite for the day.

NOTE: Always promote a discussion on any of the topics covered in the Tool Box Talks. Should any question arise that you cannot answer, don’t hesitate to contact your Employer.

Shepformation... The Shepley Newletter

  • Civic Rent: Beer for a Good Cause

    Where to Buy Civic Rent is a limited edition lager

    Read More
  • COVID-19 Response & Updates

    At Shepley, nothing is more important to us than t

    Read More
  • Pay It Forward with House Wine at Luke’s

    Inspired by Shepley Wood Products & Barnstable

    Read More
  • Class of 2020 Flyover wins PRISM Award

    We are excited to share that Shepley Wood Products

    Read More

Newsletter Sign Up

Central Location:

Hyannis Office

216 Thornton Drive, Hyannis, MA 02601
Phone: 508-862-6200
Toll-free: 800-227-7969
Facsimile: 508-862-6012
Directions

Shepley Showcase

75 Ben Franklin Way, Hyannis, MA 02601
Phone: 508-862-6228
Toll-free: 877-909-7227
Facsimile: 508-862-6047
Directions

Nantucket Office

6 Lovers Lane, Nantucket, MA 02554
Phone: 508-325-0400
Facsimile: 508-325-0359
Directions

Wellfleet Office

2238 Route 6, Wellfleet, MA 02667
Phone: 508-349-2280
Facsimile: 508-349-3078
Directions